PRIMERGY TX150 S7 Installation Guide Page 75

  • Download
  • Add to my manuals
  • Print
  • Page
    / 100
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 74
TX150 S7 Options Guide 71
Conversion from a floorstand model to a rack model
Ê Lift off the right-hand side cover.
I The right-hand side cover is no longer required.
Ê Lay the server on its right-hand side.
V CAUTION!
Get a second person to help you do this. The server can weigh up to
35 kg.
Figure 63: Removing the foot mounting rail
Ê Loosen the three screws (1) of the foot mounting rail.
Ê Slide the foot mounting rail backward (2) until the hooks disengage.
Ê Take off the foot mounting rail.
I The foot mounting rail is no longer required.
The drive cage for the accessible drives is constructed in such a way that the
accessible drives and the front panel module can be taken out simply, turned
through 90° to the left, and then be reinstalled.
Ê Remove the dummy covers from the drive cage (figure 12 on page 33).
Ê Unplug the cables from the system board or the accessible drives and
remove the drives from the drive cage.
1
0 0 0
Page view 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 99 100

Comments to this Manuals

No comments