TX150 S7 Options Guide 63
9 Conversion standard PS to hot-
plug PS
V CAUTION!
Follow the safety instructions in the chapter "Safety instructions" on
page 11.
The standard power supply can be replaced by a hot-plug power supply. The
hot-plug power supply consists of up to two power supply modules. The
upgrade kit contains only one power supply module (for power supply
redundancy the second power supply module must be additionally ordered).
The upgrade kit for the hot-plug power supply consists of the following parts:
PS cage with Power backplane (incl.power cables)
one power supply unit
dummy cover (if only one power supply module is installed, you have to
install the dummy cover in the second bay)
several screws
anti-tilt bracket
Ê Open the server and remove the system fan as described in the chapter
"Preparation" on page 19.
Ê Disconnect all power cables from the system board and the drives (see the
cabling plans in the Appendix).